saltar al contenido Saltar a navegación

Bosch Security and Safety Systems Spain

FAMILIA DE PRODUCTOS

Bosch EVAX System - High-rise Applications

Bosch EVAX System - High-rise Applications

Central maestra, 16 conmut./entradas

CTN HMB-MP16
Nº de producto F.01U.201.668

Bosch EVAX System - High-rise Applications

Central distribuida, 4 circuitos audio

CTN HMB-DP
Nº de producto F.01U.201.674

Bosch EVAX System - High-rise Applications

Central distribuida, 4 circ tel incendio

CTN HMB-DP/P
Nº de producto F.01U.201.675

Bosch EVAX System - High-rise Applications

Central distribuida, 16 circuitos audio

CTN HMB-DP-42
Nº de producto F.01U.201.676

Communication Type: RS‑485 standard
Data Rate: 1 MB
Frequency: 1.024 MHz
Wire Type: Twisted pair, Category 5 UTC
Current: 50 mA maximum
Impedance: 120 Ω maximum between panels
Voltage (peak to peak): 5 V maximum
ASC: Alarm: 30 mA, Standby: 30 mA
DCC: Alarm: 80 mA, Standby: 80 mA
IOI: Alarm: 20 mA, Standby: 20 mA
MMC: Alarm: 45 mA, Standby: 45 mA
SLC: Alarm: 6 mA, Standby: 6 mA
SSC: Alarm: 25 mA, Standby: 25 mA
Type: Two 12 VDC Gel Cell in series
Current (battery charging): 800 mA
Current (input): Typical Load: 0.28 A Maximum Load: 0.4 A
Capacity: Minimum: 24 VDC, 7 Ah Maximum: 24 VDC, 18 Ah
Input (primary): 120 VAC at 60 Hz
Input current: 0.28 A at 120 VAC
Input (circuits): all circuits at 24 VDC

Amplificador con micrófono, 25W, gris

CTN EVX-25E
Nº de producto 4.998.143.753

A 25 W amplifier with built-in tone generator. The module is capable of operating as a slave amplifier when connected to an EVAX25 panel which supplies the source audio. The module can also operate as a stand‑alone voice evacuation system with only tone and microphone amplification.

Amplificador con micrófono, 50W, gris

CTN EVX-50E
Nº de producto 4.998.143.758

A 50 W amplifier with built-in tone generator. The module is capable of operating as a slave amplifier when connected to an EVAX50 panel which supplies the source audio. The module can also operate as a stand‑alone voice evacuation system with only tone and microphone amplification.

Amplificador con micrófono, 100W, gris

CTN EVX-100E
Nº de producto 4.998.143.761

A 100 W amplifier with built-in tone generator. The module is capable of operating as a slave amplifier when connected to an EVAX100 panel which supplies the source audio. The module can also operate as a stand‑alone voice evacuation system with only tone and microphone amplification.

Módulo conmutación amplificador respaldo

CTN EVB-BA100
Nº de producto F.01U.201.682

Switches to a backup amplifier in the event of a primary amplifier failure

Transformador alimentación EVX-25E

CTN EVX-T2885
Nº de producto 4.998.143.738

Open frame, 28 VAC @ 100 VA

Transformador alimentación EVX-50E/100E

CTN EVX-T17528
Nº de producto 4.998.143.739

Open frame, 28 VAC @ 180 VA

Interfaz audio/módulo

CTN MB-AMI
Nº de producto F.01U.201.678

Controls 2 EVX-25E/50E/100E Expander Modules in Distributed Panels

Control sistema audio

CTN MB-ASC
Nº de producto F.01U.201.689

The MB-ASC Audio system control provides digitally-stored message control over two RS232 communication ports.

Comunicaciones/control de datos

CTN MB-DCC
Nº de producto F.01U.201.688

A programmable data communications controller that provides digitally-stored message control. Installed in Master panel.

Equipo teléfono incendio

CTN MB-FH
Nº de producto F.01U.201.684

Color red, 6 mount in MB‑TC cabinet

Conector teléf. incendio, placa 1 hueco

CTN MB-FJ
Nº de producto F.01U.201.683

Brushed stainless steel single gang plate

Tarjeta fibra óptica

CTN MB-FO
Nº de producto F.01U.201.681

Provides termination for Fiber Optic communications between the Master Panel and the Distributed Panels

Interfaz teléfono incendio

CTN MB-FPI
Nº de producto F.01U.201.679

Provides 4 supervised Class B Fire Phone circuits in distributed panel (4 max 16 circuits). When more than one is used in a HMB‑DP Master Panel a MB‑FPO2 Fire Phone Output Adapter is required for each.

Salida teléfono incendio

CTN MB-FPO2
Nº de producto F.01U.201.680

Extra terminal card that must be used with the 2nd, 3rd and 4th MB‑FPI cards in a Distributed Panel

Central teléfono incendio, mont. superf.

CTN MB-FS
Nº de producto F.01U.201.686

Coil cord, thumb turn latch, cabinet: red, surface/semi-flush mount

H x W x D: 12-3/4 x 7 1/4 x 3 3/4 in.

Relé placa base, clase A/clase B

CTN MB-MBK
Nº de producto F.01U.201.677

Contains audio output relays and protection devices that allow four Class B speaker loop outputs. A maximum of two MB‑MBK cards allow eight Class B or four Class A speaker circuits per Distributed Panel

Estructura teléf. incendio maestro (MP)

CTN MB-MFA
Nº de producto F.01U.201.671

Master Panel's Fire Phone handset, plate and interface PC board

Control micrófono maestro

CTN MB-MMC
Nº de producto F.01U.201.690

The MB-MMC Master microphone control provides microphone system control and status display.

Placa base/remoto

CTN MB-MBR
Nº de producto F.01U.201.691

Provides card slots (can be extended up to seven) for MB‑AMI and MB‑FPI and two MB‑MBK

Interfaz salida extendida, 16 salidas

CTN MB-OI
Nº de producto F.01U.201.673

Adds 16 outputs to Master Panel

Fuente de alimentación

CTN MB-PWR
Nº de producto F.01U.201.692

A nominal 24 VDC power supply and battery charger

Tarjeta conmut./LED (añade 16 conmut.)

CTN MB-SLC
Nº de producto F.01U.201.669

16 switches and LEDs for manual control at Master Panel

Tarjeta escaneado conmutadores

CTN MB-SSC
Nº de producto F.01U.201.670

Controls up to eight Switch/LED Cards (128 switches). Multiple (up to 16) MB‑SSC cards can be used for a system capacity of 2048 switches. Field additions or replacement only.

Gabinete equipo teléfono incendio

CTN MB-TC
Nº de producto F.01U.201.685

Cabinet: charcoal gray, surface/semi-flush mount, key lock

H x W x D: 27 x 14-1/2 x 4 in.

Estación para director, cable blindado

CTN MB-WS
Nº de producto F.01U.201.687

Cabinet: red, surface/semi-flush mount

H x W x D: 12‑3/4 x 7‑1/4 x 3‑3/4 in.

Interfaz entrada extendida, 16 entradas

CTN MB-XI
Nº de producto F.01U.201.672

Adds 16 inputs to Master Panel

Título Tipo Idioma
Título
CSFM
Tipo
PDF
Idioma
Título
UL (UOXX.S5579 - CONTROL UNIT ACCESSORIES, SYSTEM)
Tipo
PDF
Idioma
Título
Especial (HMB Configuration Form)
Tipo
XLS
Idioma
en-US 
Título
Hoja de datos
Tipo
PDF
Idioma
en-US 
Título
Manual de instalación (B-5001 Rev E EVAX 25-50-100 Install 11-14-8)
Tipo
PDF
Idioma
en-US 
Título
Manual de instalación (B-5002 Rev E EVX-25E.50E.100E Install (12.07))
Tipo
PDF
Idioma
en-US 
Título
Manual de instalación (B-5010 Rev C HMX Install)
Tipo
PDF
Idioma
en-US 
Título
Manual de instalación (B-5030 Rev C EVX-BA)
Tipo
PDF
Idioma
en-US 
Título
Manual de instalación (B-5037 Rev B MX-FH)
Tipo
PDF
Idioma
en-US 
Título
Manual de instalación (B-5038 Rev C MX-FJ)
Tipo
PDF
Idioma
en-US 
Título
Manual de instalación (B-5042 Rev B MX-TC)
Tipo
PDF
Idioma
en-US 
Título
Manual de instalación (B-5062 REV C MX-FS-WS)
Tipo
PDF
Idioma
en-US 
Título
Manual de instalación (B-5063 Battery Y Cable Rev A (12.07))
Tipo
PDF
Idioma
en-US 
forward-right_adjusted