Buttons (through screw-terminal connectors) |
5 pre-programmed 15 programmable zone/function buttons 3 supervised programmable optional emergency buttons 2 connections for each button; 23 buttons share 6 common VCCs (3V3 - DC) Each button has short circuit protection |
LEDs connected to buttons (through screw-terminal connectors) |
This kit supports open drain outputs with max. 5 mA per output. Using the internal supply, a maximum of 100 mA can be sourced for all outputs. The kit also provides an external power supply for lighting LEDs of external normal buttons. 2 connections (VCC & open collector) are available for each LED connected to a button. In total, 38 LEDs share 10 common MIX_PWR_LED. These LEDs are supplied with 5 V DC using the internal power supply. The connected LEDs are supplied with 24 V DC using the external power supply. Each LED circuit has short-circuit protection. |
Power LED (through screw-terminal connectors) |
Driven by MIX_PWR_LED (5 V DC or 24 V DC) 2 connections (VCC & open collector) |
Fault LED (through screw-terminal connectors) |
Driven by MIX_PWR_LED (5 V DC or 24 V DC) 2 connections (VCC & open collector) |
Alarm LED (through screw-terminal connectors) |
Driven by MIX_PWR_LED (5 V DC or 24 V DC) 2 connections (VCC & open collector) |
Included LCD display kit |
A flat ribbon cable connects the display to the call station kit mainboard. The ribbon cable length is +/- 300 mm |
Others (through screw-terminal connectors) |
1 audio source (line in) 1 supervised microphone input (eg. LBB9081) capsule and PTT button connection (input & VCC) with short-circuit protection. 1 loudspeaker connection, 1 additional +24 V DC power supply |
External connectors |
1 call station bus connector (control data + audio + power supply, RJ-45) 1 EXT connector (RJ-12, e.g. for call station extension) |
Nominal voltage |
24 V DC (-10%/+30%) |
Maximum voltage range |
15–58 V DC |
Nominal current consumption for main power supply |
< 100 mA |
External power supply for lighting, without extensions |
< 80 mA/24 V < 110 mA/18 V |
Internal power supply for lighting, without extensions |
< 150 mA/24 V < 200 mA/18 V |
CAN interface |
10, 20, or 62.5 kbit/s |
Maximum mic input level |
-21 dBu |
Maximum line input level |
+4 dBu |
NF output |
Balanced |
Nominal level |
+6 dBu |
Maximum level |
+12 dBu |
Frequency response |
200–16,000 Hz, +0/-3 dB |