Bosch Security and Safety Systems Nordics
- Multiple lines
- CSV
- Copy Paste
-
Quantity Changed
How to format the CSV Spreadsheet
Please upload CSV file (2003 CSV format) to be imported into your cart. This file can have multiple worksheets, and each of them must contain on the first column material number (required), on the second column amount to be ordered (empty means 1 item) and on third column you can add commision text (optional).
Example
You can insert an error message here. How to prepare cell to copy
Enter the material numbers and quantities required and click 'upload'. The products and quantities entered will be shown for you to review in the tab 'Add multiple items' and click right after on 'add to cart'.
Example
- 2608630030
- F00Y100947 5
- F00Y100947;5
- 2608630030 12
- 2608630030;10
Copy and paste prepared cell
- Home
- Product Segments
- Fire Alarm Systems - EN54
- Automatic Fire Detectors
- Sign In/ Register
-
Quick add
- Multiple lines
- CSV
- Copy Paste
-
Quantity Changed
How to format the CSV Spreadsheet
Please upload CSV file (2003 CSV format) to be imported into your cart. This file can have multiple worksheets, and each of them must contain on the first column material number (required), on the second column amount to be ordered (empty means 1 item) and on third column you can add commision text (optional).
Example
You can insert an error message here. How to prepare cell to copy
Enter the material numbers and quantities required and click 'upload'. The products and quantities entered will be shown for you to review in the tab 'Add multiple items' and click right after on 'add to cart'.
Example
- 2608630030
- F00Y100947 5
- F00Y100947;5
- 2608630030 12
- 2608630030;10
Copy and paste prepared cell
Product subcategory
Basic functions
PRODUCT FAMILY
AVENAR detector 4000
- Highly reliable and accurate thanks to Intelligent Signal Processing (ISP)
- Earliest detection of lightest smoke with dual-optical versions (Dual-Ray technology)
- Monitors environment for electromagnetic influence for fast root-cause analysis
- Automatic and manual address setting



Back box ceiling-mount
CTN FAA-500-BB | Product No. 4.998.151.302
- Installation in false ceilings
- Easy to install
Back box for damp rooms, surface-mount
CTN FAA-500-SB-H | Product No. F.01U.510.166
- Damp room sealing for installation in humid areas
- Optional flush or surface cabling
Base attachment
CTN FDB291 | Product No. F.01U.335.165
- Base attachment for OOH740-A9-Ex
- Compact and robust design
- High level of resistance to temperature fluctuations, humidity, corrosion and contamination
Base attachment wet
CTN FDB295 | Product No. F.01U.335.589
- Base attachment for OOH740-A9-Ex
- Integrated additional rubber seal for applications in cold or wet environments
- Compact and robust design
- High level of resistance to temperature fluctuations, humidity, corrosion and contamination
Base extension with damp room sealing
CTN MSC 420 | Product No. 4.998.113.025
- Damp room sealing for installation in humid areas
- Easy to install
- Surface mounting
Base for Dual-Optical Detector for Ex Ar
CTN FDB201 | Product No. F.01U.332.583
- Compact and robust design
- High level of resistance to temperature fluctuations, humidity, corrosion and contamination
- Safe insertion of an designation plate
Detector base
CTN FAA-500 | Product No. 4.998.151.297
- Screw terminals for safe and secure electrical connection
- Easy to install
Dual-optical detector, explosive area
CTN OOH740-A9-EX | Product No. F.01U.332.582
- Compact and robust design
- Earliest detection of lightest smoke with dual-optical or thermal detection
- Highly reliable and accurate
- High level of resistance to temperature fluctuations, humidity, corrosion and contamination
- High resistance to interference
Duct detector housing with base
CTN FAD-420-HS-EN | Product No. F.01U.029.411
- Use in ventilation systems with air velocities from 1 m/s to 20 m/s
- For the activation of fans, door controls or external display devices an optional Relay Board can be installed
- A clear section on the frosted cover allows observing the alarm LED of the integrated FAD-425-O-R Detector
- Control to prevent unwanted removal of the cover
- Easy installation of the FAD-425-O-R Detector
- Maintains LSN loop functions in the event of wire interruption or short-circuit thanks to two integrated isolators
Dust protection, 10pcs
CTN SSK400 | Product No. 4.998.035.312
- Protection against dust or other dusty particles before operation
- Easily mounted and removed
PRODUCT FAMILY
FAP‑520 Automatic Fire Detectors LSN improved version
- Modern, ultra-flat design
- Smooth, easily-cleaned detector surface
- Innovative fastening mechanism
- High reliability
- Maintains LSN loop functions in the event of wire interruption or short-circuit thanks to two integrated isolators
- Extended system parameters of improved LSN technology


PRODUCT FAMILY
FAS-420-TM Aspiration smoke detector series LSN improved
- For connecting to the fire panels FPA-5000 and FPA‑1200 with LSN improved technology
- High deceptive alarm immunity with intelligent signal processing LOGIC·SENS
- Innovative fire source identification technology allows the exact location of the fire to be pinpointed by monitoring up to five distinct zones
- Innovative airflow monitoring including single-hole monitoring detects obstruction and breakage
- Installation and commissioning made easy by plug-and-play function
- Easy to diagnose using FAS‑ASD‑DIAG Diagnostic Software
- Simple implementation of the pipe system planning through patented Aspiration reducing Film Sheets
- Preservation of LSN loop functions in the event of wire interruption or short-circuit through two integrated isolators



PRODUCT FAMILY
FAS‑420 Aspiration smoke detector series LSN improved
- Connectable to the fire panels FPA‑5000 and FPA‑1200 with the improved LSN technology
- High deceptive alarm immunity with intelligent signal processing LOGIC·SENS
- Innovative airflow monitoring including single-hole monitoring detects obstruction and breakage
- Initial set-up made easy by automatic initialization
- Easy diagnostics through flash code on the Detector Module or by using the FAS‑ASD‑DIAG diagnostic software
- Simple implementation of the pipe system planning through patented Aspiration reducing Film Sheets
- Maintains LSN loop functions in the event of wire interruption or short-circuit thanks to two integrated isolators
- SL-versions: Noise reduction to 38 dB(A) by extremely quiet fan and up to 34 dB(A) with additional sound absorber



PRODUCT FAMILY
FCP‑320/FCH‑320 Conventional Automatic Fire Detectors
- High reliability of detection thanks to evaluation electronics
- Active adjustment of the threshold (drift compensation) if the optical sensor becomes dirty
- Activation of a remote external detector alarm display possible
- Mechanical removal lock(can be activated/deactivated)
- Dust-repellent labyrinth and cap construction

PRODUCT FAMILY
FCP‑500 Conventional Automatic Fire Detectors
- Modern, ultra-flat design
- Matches the surrounding decor by using color toning inserts
- Smooth, easily-cleaned detector surface
- Innovative fastening mechanism
- High reliability

PRODUCT FAMILY
FCS-320-TM Conventional aspiration smoke detector series
- For connecting to conventional fire panels
- High deceptive alarm immunity with intelligent signal processing LOGIC·SENS
- Innovative fire source identification technology allows the exact location of the fire to be pinpointed by monitoring up to five distinct zones
- Innovative airflow monitoring including single-hole monitoring detects obstruction and breakage
- Installation and commissioning made easy by plug-and-play function
- Easy to diagnose using FAS‑ASD‑DIAG Diagnostic Software
- Simple implementation of the pipe system planning through patented Aspiration reducing Film Sheets


PRODUCT FAMILY
FCS-320-TP Conventional aspiration smoke detector series
- For connecting to conventional fire panels
- High deceptive alarm immunity with intelligent signal processing LOGIC·SENS
- Innovative airflow monitoring including single-hole monitoring detects obstruction and breakage
- Initial set-up made easy by automatic initialization
- Easy diagnostics through flash code on the Detector Module or by using the FAS‑ASD‑DIAG diagnostic software
- Simple implementation of the pipe system planning through patented Aspiration reducing Film Sheets


PRODUCT FAMILY
Fireray 50/100RV Linear beam detectors
- Extended monitoring area
- Transmitter, receiver, and evaluating unit integrated into a compact housing
- Electronic help for detector alignment and automatic detector calibration procedure
- Automatic compensation for contamination
- LED display in control unit for various operating states
- Adjustable alarm thresholds
Flame detector flameproof Ex d, IR3
CTN 016519 | Product No. F.01U.279.764
- Suitable for explosive areas of the zones 1, 21, 2 and 22 (ATEX and IECEx certified)
- Sensitivity according to EN 54-10 Class 1: 0.1 m² flames at 25m
- Low risk of false alarms due to different IR wavelengths and a combination of filters and signal processing techniques
- Reliable operation, even if the lens is contaminated by a layer of oil, dust, water-vapour, or ice
- Selectable response time
- 2-wire or 4-wire configuration via DIP switch settings
Flame detector, IR3
CTN 016589 | Product No. F.01U.279.762
- Sensitivity according to EN 54-10 Class 1: 0.1 m² flames at 25m
- Low risk of false alarms due to different IR wavelengths and a combination of filters and signal processing techniques
- Reliable operation, even if the lens is contaminated by a layer of oil, dust, water-vapour, or ice
- Selectable response time
- 2-wire or 4-wire configuration via DIP switch settings
Heating element
CTN MH 400 | Product No. 4.998.025.373
- For applications where condensation is likely
- Power-supplied by panel or separate power supply unit
Housing for concrete ceilings
CTN FAA-500-CB | Product No. F.01U.508.713
- Installation in concrete ceilings
- Easy to install
Label plate large
CTN TP8 400 | Product No. 4.998.084.710
- Easy detector marking and identification
- Self-adhesive labels can be used
Label plate small
CTN TP4 400 | Product No. 4.998.084.709
- Easy detector marking and identification
- Self-adhesive labels can be used
Linear beam detector
CTN FIRERAY5000-EN | Product No. F.01U.290.197
- Extended monitoring range
- Up to 2 detectors per system controller
- Two pairs of fire and fault relays (one per detector)
- Transmitter and receiver integrated into a compact housing
- Integral LASER alignment
- Self-alignment during operation
- Remote control unit at eye level for easy installation and programming
- Automatic compensation for contamination
- Control unit with LED and LCD displaying - various operating states
- Adjustable alarm thresholds
- Building shift compensation
Protective cage
CTN SK 400 | Product No. 4.998.025.369
- Protection against damage from hits or other heavy impacts
- Easily mounted and removed
Remote indicator
CTN FAA-420-RI-ROW | Product No. F.01U.289.120
- 360° view, for both wall mount and ceiling mount
- Easy cabling thanks to cable ties bracket and all direction knock-out holes
- Long life and robust construction housing
- Efficient LED
Remote indicator for DIN application
CTN FAA-420-RI-DIN | Product No. F.01U.289.620
- 360° view, for both wall mount and ceiling mount
- Easy plug in installation
- Easy cabling thanks to cable ties bracket and all direction knock-out holes
- Long life and robust construction housing
- Efficient LED
Safety barrier
CTN SB3 | Product No. 4.998.112.085
- Suitable for applications with Ex detectors
- Input/Output Module included
- Impact-proof and scratch-resistant synthetic material
- Large opening for reuse of existing boreholes
- Screwless connection terminals
Spring for wooden/concrete ceilings
CTN FAA-500-SPRING | Product No. F.01U.510.028
- For installation in concrete and wooden ceilings
- Easy to install
Trim ring, colored
CTN FAA-500-TR-P | Product No. 4.998.151.296
- Easy to install
- No additional mounting material needed
Trim ring, white
CTN FAA-500-TR-W | Product No. 4.998.151.295
- Easy to install
- No additional mounting material needed
PRODUCT FAMILY
Wireless Fire Detection System
- Multihop mesh technology
- High communication reliability due to redundant transmission paths and to a dual band (433MHz, 868MHz)
- Long range thanks to an extended transmission path as every radio devices is used as a signal repeater (up to 3 hops)



Linear heat detector
CTN FCS-LWM-1 | Product No. F.01U.026.138
- Usable in constricted spaces and under extreme environmental conditions
- Usable in Ex-zones 1,2, 21, 22
- Resistant to mechanical and chemical influences, corrosion, humidity and dust
- Usable for DIN EN 54-5:2000 classes A1, A2, B, C
- Simple installation and initial set-up
- Minimal maintenance costs through continual self-monitoring of the sensor cable
- Configurable response temperature
- Test key for maintenance (simulates alarm and malfunction).