Skip to content Skip to navigation

Bosch Security and Safety Systems Thailand

PRODUCT FAMILY

FPA‑1000 Analog Addressable Fire Panels

FPA‑1000 Analog Addressable Fire Panels

Fire panel, 2 SLC & networking

Commercial Type No. FPA-1000-V2
Product No. F.01U.213.945

Supervision Supervised for the presence of AC power
Voltage 120 VAC, 60 Hz, 1.1 A maximum, or240 VAC, 50 Hz, 0.6 A maximum
Voltage 24 VDC
Supervision Supervised for the presence of AC power
Current consumption (standby) 1.25 A maximum
Current consumption (alarm) 5 A maximum 1.0 A maximum shared between panel and SLC(s) Panel ≤ 250 mA SLC 1 = 60 mA/card + 220 mA/loop maximum SLC 2 = 60 mA/card + 220 mA/loop maximum 4.0 A maximum shared between NACs, Option Bus, and AUX power NACs (non-synchronized) NAC 1 =2.5 A maximum NAC 2 = 2.5 A maximum NACs (synchronized) NAC 1 + NAC 2 in total = 2.75 A maximum Option Bus = 0.5 A maximum AUX/FWR = 0.5 A maximum AUX/RST = = 0.5 A maximum
Battery capacity 7.0 Ah minimum, 40 Ah maximum
Charge current 2.0 A maximum
Fuse 15 A blade-type
Suitable battery type Two 12 VDC in series (7 Ah or 18 Ah in enclosure, 24 Ah or 38 Ah in additional battery box) Recommended Manufacturers: POWER SONIC: PS-1270, PS-12170, PS‑12180 YUASA: NP7-12, NPG18-12
Maintenance Replace batteries when they fail the Battery Load test
AUX/FWR Full Wave Rectified 500 mA at 24 V FWR (17 to 31 VRMS), non‑switched, power-limited, unfiltered, non‑supervised
AUX/RST Resettable 500 mA at 24 V FWR (17 to 31 VDC), switched, power-limited, filtered, non‑supervised
Line impedance for ground fault detection (Option Bus, SLC, NAC, secondary power circuit, City Tie/Local Energy, AUX) 15 kΩ
Voltage Nominal 12 VDC, power-limited, supervised
Current 500 mA maximum
Configuration 1 Class B
Circuit wiring distance 4000 ft. (1219 m) maximum, depending on wire gage and connected devices
Mainboard NACs Two (NAC 1 and NAC 2)
NAC power from panel Nominal 24 V FWR (17 to 31 VRMS), regulated, power-limited, supervised2.5 A per NAC, maximum current limited to overall 4.0 A shared among AUX power, Option BUS, and NACs

Analog point programmer, hand-held

Commercial Type No. D5070
Product No. 4.998.800.577

Used to program address settings on EEPROM‑programmable analog devices

Analog sensor base, 4"

Commercial Type No. FAA-325-B4
Product No. F.01U.133.061

Is combined with analog addressable detectors that use the advanced digital communication protocol to provide early fire warning for life safety and property protection

Analog sensor base with sounder, 6"

Commercial Type No. FAA-325-B6S
Product No. F.01U.133.063

Contains an addressable sounder which provides an audible alarm in the immediate vicinity and only works in combination with one of the FAH‑325, FAI-325, or FAP‑325 analog sensors

Analog standard base, 4"

Commercial Type No. FAA-440-B4
Product No. F.01U.163.849

Standard 4-inch base. Used in combination with FAP-440 and FAH-440 detectors to provide early fire warning for life safety and property protection.

Analog heat detector head, fixed/ROR

Commercial Type No. FAH-440
Product No. F.01U.163.842

Use with FAA‑440 family bases and FAP-1000 Analog Addressable Fire Panels to provide general property protection

Analog photoelectric detector head, 24V

Commercial Type No. FAP-440
Product No. F.01U.163.843

Analog photoelectric smoke detector used with FAA‑440 bases and FAP-1000 fire panels

Analog detector head, dual, heat/CO

Commercial Type No. FAP-440-DTC
Product No. F.01U.163.847

Analog dual-photoelectric smoke/heat multi-criteria detector used with FAA‑440 bases and FAP-1000 fire panels

Dual input module for FPA-1000

Commercial Type No. FLM-325-2I4
Product No. F.01U.133.068

Provides two independent contact monitoring circuits to monitor Normally Open (NO) or Normally Closed (NC) dry contact types of fire alarm devices

Dual relay module, 2A

Commercial Type No. FLM-325-2R4-2A
Product No. F.01U.168.098

Provides 2 A current at two independently-controlled Form C contacts for a variety of Normally Open and Normally Closed applications, compatible with 254 addresses

Dual relay module with isolator, 2A

Commercial Type No. FLM-325-2R4-2AI
Product No. F.01U.168.099

Provides 2 A current with built-in short circuit isolator circuitry at two independently-controlled Form C contacts for a variety of Normally Open and Normally Closed applications, compatible with 254 addresses

Dual relay module, 8A

Commercial Type No. FLM-325-2R4-8A
Product No. F.01U.168.100

Provides 8 A current at two independently-controlled Form C contacts for a variety of Normally Open and Normally Closed applications, compatible with 254 addresses

Dual relay module with isolator, 8A

Commercial Type No. FLM-325-2R4-8AI
Product No. F.01U.168.101

Provides 8 A current with built-in short circuit isolator circuitry at two independently-controlled Form C contacts for a variety of Normally Open and Normally Closed applications, compatible with 254 addresses

Conventional zone module for FPA-1000

Commercial Type No. FLM-325-CZM4
Product No. F.01U.133.067

Enables the FACP to interface and monitor up to 25 conventional devices depending on the device type such as two‑wire smoke detectors or pull stations

Contact monitor, class A, 4"

Commercial Type No. FLM-325-I4-A
Product No. F.01U.168.102

Can be wired for Class A or Class B circuits, mounted to a cover plate for a 4‑inch square or double gang electrical back box, bi‑colored LED provides module status, compatible with 254 addresses

Contact monitor with isolator class A 4"

Commercial Type No. FLM-325-I4-AI
Product No. F.01U.168.103

Can be wired for Class A or Class B circuits, has built‑in short circuit isolator circuitry, mounted to a cover plate for a 4‑inch square or double gang electrical back box, bi‑colored LED provides module status, compatible with 254 addresses

Short circuit isolator for FPA-1000

Commercial Type No. FLM-325-ISO
Product No. F.01U.133.071

Isolates a shorted section on a specific polling circuit from the rest of the system to minimize the loss of communication

Supervised output module, Class A/B

Commercial Type No. FLM-325-NA4
Product No. F.01U.168.104

Can be wired for Class A or Class B circuits, compatible with 254 addresses

Supervised output module, isolator, A/B

Commercial Type No. FLM-325-NAI4
Product No. F.01U.168.105

Built-in short circuit isolator circuitry, can be wired for Class A or Class B circuits, compatible with 254 addresses

Analog manual station, single, red

Commercial Type No. FMM-325A
Product No. F.01U.246.085

The single‑action manual station is UL listed for commercial fire applications and meets Americans with Disabilities Act (ADA) requirements. Set the address on the polling circuit by programming an EEPROM microchip with the D5070 Analog point programmer.

Analog manual station, double, red

Commercial Type No. FMM-325A-D
Product No. F.01U.246.087

The double‑action manual station is UL listed for commercial fire applications and meets Americans with Disabilities Act (ADA) requirements. Set the address on the polling circuit by programming an EEPROM microchip with the D5070 Analog point programmer.

LCD annunciator FPA-1000 without control

Commercial Type No. FMR-1000-RA
Product No. F.01U.066.880

LCD annunciator without system control capability for use with the FPA‑1000 Analog Addressable Fire Panels

LCD annunciator FPA-1000 with control

Commercial Type No. FMR-1000-RCMD
Product No. F.01U.066.879

LCD annunciator with system control capability for use with FPA‑1000 Analog Addressable fire Panels

Plug-in SLC module for FPA-1000

Commercial Type No. FPE-1000-SLC
Product No. F.01U.073.062

Provides a Signaling Line Circuit (SLC) for connection of analog devices to the FPA‑1000 Analog Addressable Fire Panels

Analog isolator base, 4"

Commercial Type No. FAA-440-B4-ISO
Product No. F.01U.164.309

4-inch base with built-in isolator. Used in combination with FAP-440 and FAH-440 detectors to provide early fire warning for life safety and property protection.

Analog standard base, 6"

Commercial Type No. FAA-440-B6
Product No. F.01U.164.308

Standard 6-inch base. Used in combination with FAP-440 and FAH-440 detectors to provide early fire warning for life safety and property protection.

Analog isolator base, 6"

Commercial Type No. FAA-440-B6-ISO
Product No. F.01U.164.307

6-inch base with built-in isolator. Used in combination with FAP-440 and FAH-440 detectors to provide early fire warning for life safety and property protection.

Analog photoelectric detector head, 24V

Commercial Type No. FAP-440-T
Product No. F.01U.163.844

Analog photo/heat detector used with FAA‑440 bases and FAP-1000 fire panels

Analog detector head, photo/heat/CO

Commercial Type No. FAP-440-TC
Product No. F.01U.163.846

Analog photo/heat/CO detector used with FAA‑440 bases and FAP-1000 fire panels

Analog dual-photoelectric detector head

Commercial Type No. FAP-440-D
Product No. F.01U.163.820

Analog dual-photoelectric smoke detector used with FAA‑440 bases and FAP-1000 fire panels

Analog detector head, dual, photo/heat

Commercial Type No. FAP-440-DT
Product No. F.01U.163.845

Analog dual-photoelectric smoke/heat multi-sensor detector used with FAA‑440 bases and FAP-1000 fire panels

CO detector (Macurco CM-E1)

Commercial Type No. FCC-380
Product No. F.01U.172.606

Carbon monoxide detector

Network card, 3-Ethernet

Commercial Type No. FPE-1000-NE
Product No. F.01U.213.933

Ethernet Networking Card for peer‑to‑peer communication in an FPA‑1000‑V2 networked system

Network card, 1-Ethernet 2-fiber optic

Commercial Type No. FPE-1000-NF
Product No. F.01U.213.943

Fiber Optic Networking Card for peer‑to‑peer communication in an FPA‑1000 networked system

Network card, 1-Ethernet 2-wired

Commercial Type No. FPE-1000-NW
Product No. F.01U.213.944

Wired Networking Card for peer‑to‑peer communication in an FPA‑1000 networked system

Power supply, RNAC 8A 24V

Commercial Type No. FPP-RNAC-8A-4C
Product No. F.01U.003.444

When connected to a panel’s option bus, the FPP-RNAC-8A-4C adds four additional NFPA 72, Class B or Class A NACs. When connected directly to the NAC output, it is also a NAC power supply for fire-protective signaling systems.

Annunciator, 8 alarm LED

Commercial Type No. D7030X
Product No. 4.998.800.536

Eight zone LEDs indicate alarm conditions.

Annunciator, 8 LED (2 supervisory)

Commercial Type No. D7030X-S2
Product No. 4.998.140.386

Two LEDs indicate supervisory conditions, six indicate alarm conditions.

Annunciator, 8 LED (8 supervisory)

Commercial Type No. D7030X-S8
Product No. 4.998.140.387

All eight zone LEDs (yellow) indicate supervisory conditions.

Annunciator expander, 8 LED

Commercial Type No. D7032
Product No. 4.998.140.388

Use with D7030X Family LED annunciators

Multiplex octal relay module

Commercial Type No. D7035
Product No. 4.998.800.539

Provide eight Form C relay outputs (w/o enclosure) for the D7024, FPD-7024, or FPA‑1000 Fire Alarm Control Panels (FACP)

Title Type Language
Title
CSFM
Type
PDF
Language
Title
FDNY-CoA
Type
PDF
Language
Title
UL
Type
PDF
Language
en-US  es-AR  pt-BR 
Title
A&E specifications
Type
DOCX
Language
en-US 
Title
CAD Drawing DWG (FPA-1000_panel_CITY_SLC_Annun)
Type
DWG
Language
en-US 
Title
Commercial Brochure
Type
PDF
Language
en-US 
Title
Datasheet (FPA-1000)
Type
PDF
Language
en-US  es-AR  th-TH 
Title
Installation manual
Type
PDF
Language
en-US  es-AR  th-TH 
Title
Quick Selection Guide
Type
PDF
Language
en-US 
Title
Release notes (v2.02.01)
Type
PDF
Language
en-US 
Title
Special (- Operating Instructions Sheet)
Type
PDF
Language
en-US  es-AR  th-TH 
Title
Special (NAC Compatibility List)
Type
PDF
Language
en-US 
Title
Special (Technical Bulletin - Compatible browsers for programming FPA-1000 panels)
Type
PDF
Language
en-US 
Title
Special (Technical Bulletin - Ring Count Event Delay)
Type
PDF
Language
en-US 
Title
Special (Technical Bulletin - Special Characters Increase Label Length)
Type
PDF
Language
en-US 
Title
Special (Technical Bulletin Internet Security)
Type
PDF
Language
en-US 
Title
Special (Technical Bulletin Sounder bases configured for Activated by host)
Type
PDF
Language
en-US 
Title
Technical bulletin (IP Communication Issue)
Type
PDF
Language
en-US 
Title
User manual
Type
PDF
Language
en-US  es-AR  th-TH 
Title
Software (Battery_Calculator_v2.02.03)
Type
ZIP
Language
en-US 
Title
Software (Offline Tool v2.02b)
Type
ZIP
Language
en-US 
Title
Software (Panel Software v2.02.01)
Type
ZIP
Language
en-US 
forward-right_adjusted