Easy Series

Dimensions (H x W x D): 37 cm x 31.8 cm x 8.5 cm (14.5 in x 12.5 in x 3.25 in)
Construction Material: Cold-rolled steel, zinc seal, 0.36 mm thick (20 Ga.)
Relative Humidity: 93% at 32°C 2°C (89.6°F 35.6°F)
Operating Temperature: -10°C to +49°C (14°F to +120°F) CE: -10°C to +40°C (+14°F to +104°F) NF A2P: -10°C +55°C (+14°F to +131°F)
Storage Temperature: -10°C to +55°C (+14°F to +131°F)
Protection Level IP 30 - IK 04
On-board Hardwire: 8 Single or dual end-of-line (2.2 k EOL) tamper point support Point 1 supports two-wire smoke detectors All points support four-wire smoke detectors Enclosure tamper input (does not reduce point capacity) Reaction time lower than 250ms
On-board: 4 PO 1 only: Configurable relay PO 2 to PO 4: Configurable solid state PO 4 only: Internal supervised speaker driver option
PO 1 Relay Rating: Contacts: 2 A with no jumper installed; resistive loads only; in a NF A2P certified installation: 1 A Output: 1.2 A with jumper installed; resistive loads only; in a NF A2P certified installation 1 A Operating Voltage: 30 VDC maximum
PO 2 to PO 4 Rating: 400 mA current sink
Users: 22 User 1: Master user Users 2 to 21: System users User 22: Duress user
Events: 500 history events, stamped with time and date
Tokens and Key Fobs: One per user (User 22 does not receive a token or key fob)
Phone line trouble voltage Trouble condition occurs when the phone line voltage is between 1.10 V and 4.75 V
AC Input Line Voltage Use a UL Listed 18 V Class 2 transformer (22 VA 50/60 Hz)
Total Alarm Power: 1.4 A (AC power and standby battery; intrusion applications only). With a 7.0 Ah battery, the following current draws apply to all outputs and devices connected to the system: Up to 170 mA for 24 hr for fire and combined fire/burglary applications Up to 1.2 A for other applications
Auxiliary Power: 12 VDC, 1.0 A maximum. Includes 110 mA for each control center connected to the system, and up to 400 mA for the programmable outputs.
Current Draw: 85 mA standby; 160 mA alarm with all outputs activated
Voltage: 12 VDC nominal (11.2 VDC to 12.3 VDC) The control panel stops processing point faults when the voltage drops below 9.5 VDC.
Battery: D126 (7 Ah) or D1218 (18 Ah) sealed, lead acid rechargeable 1.7 A maximum recharging current Low battery condition occurs when battery drops below 12 VDC If AC power fails and the battery drops below 9.5 VDC, the control panel stops processing point faults. Disconnect the battery under these conditions. Maximum auxiliary current to recharge standby battery within 72 hours: 12 V, 7 Ah Battery: 400 mA 12 V, 18 Ah Battery: 900 mA In an NF A2P certified installation, use a battery Yuasa NP17-12IFR

Ethernet Communication Module

Commercial Type No. B426
Product No. F.01U.324.383

Supports two-way communications over Ethernet networks for compatible control panels

Plug-in Communicator Interface

Commercial Type No. B450
Product No. F.01U.323.797

Supports two-way IP communications using plug-in cellular communicators for compatible control panels

Title Type Language
Title Type
PDF
Language
en-US 
Title Type
PDF
Language
Title Type
PDF
Language
Title Type
PDF
Language
Title Type
PDF
Language
Title Type
PDF
Language
Title Type
PDF
Language
Title Type
PDF
Language
Title Type
PDF
Language
Title Type
PDF
Language
forward-right_adjusted