FCP‑320/FCH‑320 Conventional Automatic Fire Detectors

FCP‑320/FCH‑320 Conventional Automatic Fire Detectors
Smoke detector optical
CTN FCP-O320
Product No. F.01U.026.293

FCP‑320/FCH‑320 Conventional Automatic Fire Detectors
Multisensor detector optical/chemical
CTN FCP-OC320-R470
Product No. F.01U.029.867

FCP‑320/FCH‑320 Conventional Automatic Fire Detectors
Multisensor detector optical/thermal
CTN FCP-OT320-R470
Product No. F.01U.029.862

FCP‑320/FCH‑320 Conventional Automatic Fire Detectors
Smoke detector, optical
CTN FCP-O320-R470
Product No. F.01U.029.857

FCP‑320/FCH‑320 Conventional Automatic Fire Detectors
Heat detector
CTN FCH-T320-R470
Product No. F.01U.029.861

FCP‑320/FCH‑320 Conventional Automatic Fire Detectors
Heat detector, DIBt protection closures
CTN FCH-T320-FSA
Product No. F.01U.026.294
Operating voltage | 8.5 V DC to 30 V DC |
Current consumption | < 0.12 mA |
Alarm output | Increase in current (alarm resistance 820 Ω or 470 Ω) |
Indicator output | Open collector connects 0 V in the event of an alarm over 3.92 kΩ |
Individual display | LED red |
Without base | Ø 99.5 x 52 mm |
With base | Ø 120 x 63.5 mm |
Housing material | Plastic, ABS |
Housing color | White, similar to RAL 9010, matt finish |
Weight without/with packaging | Approx. 80 g / approx. 120 g |
FCP-OC320 / FCP-OC320-R470 | Approx. 85 g / approx 130 g |
Protection class as per EN 60529 | IP 41, IP 43 with FAA-420-SEAL or MSC 420 |
Permissible relative humidity | 95% (non-condensing) |
Permissible air speed | 20 m/s |
Permissible operating temperature | -20 °C to +50 °C |
FCP-O320 / FCP-O320-R470 | -20 °C to +65 °C |
FCP-OC320 / FCP-OC320-R470 | -10 °C to +50 °C |
Monitoring area | Max. 120 m2 (Heed local guidelines!) |
FCH-T320 / -R470 / -FSA | Max. 40 m2 (Heed local guidelines!) |
Maximum installation height | 16 m (Heed local guidelines!) |

Detector base
CTN MS 400
Product No. 4.998.021.535
Detector base for surface mounted and flush-mounted cable feed, not branded.

Base sounder, white
CTN MSS300-WH-EC
Product No. 4.998.120.501
Control through fire panel via interface

Heating element
CTN MH 400
Product No. 4.998.025.373
usable at locations where the functional safety of the detector might be impaired by condensation

Dust protection, 10pcs
CTN SSK400
Product No. 4.998.035.312
Protective dust cover for automatic point type detectors.
Delivery unit is 10.

Label plate small
CTN TP4 400
Product No. 4.998.084.709
Support plate for detector identification.
Delivery unit is 50.