FPA‑1000 Analog Addressable Fire Panels

FPA‑1000 Analog Addressable Fire Panels
Fire panel, 2 SLC & networking
CTN FPA-1000-V2
Product No. F.01U.213.945

FPA‑1000 Analog Addressable Fire Panels
Analog/networkable panel, no transformer
CTN FPA-1000-LT
Product No. F.01U.082.721

FPA‑1000 Analog Addressable Fire Panels
Fire panel, 2 SLC & networking, no encl.
CTN FPA-1000-LC
Product No. F.01U.214.787
Supervision | Supervised for the presence of AC power |
Voltage | 120 VAC, 60 Hz, 1.1 A maximum, or240 VAC, 50 Hz, 0.6 A maximum |
Voltage | 24 VDC |
Supervision | Supervised for the presence of AC power |
Current consumption (standby) | 1.25 A maximum |
Current consumption (alarm) | 5 A maximum 1.0 A maximum shared between panel and SLC(s) Panel ≤ 250 mA SLC 1 = 60 mA/card + 220 mA/loop maximum SLC 2 = 60 mA/card + 220 mA/loop maximum 4.0 A maximum shared between NACs, Option Bus, and AUX power NACs (non-synchronized) NAC 1 =2.5 A maximum NAC 2 = 2.5 A maximum NACs (synchronized) NAC 1 + NAC 2 in total = 2.75 A maximum Option Bus = 0.5 A maximum AUX/FWR = 0.5 A maximum AUX/RST = = 0.5 A maximum |
Battery capacity | 7.0 Ah minimum, 40 Ah maximum |
Charge current | 2.0 A maximum |
Fuse | 15 A blade-type |
Suitable battery type | Two 12 VDC in series (7 Ah or 18 Ah in enclosure, 24 Ah or 38 Ah in additional battery box) Recommended Manufacturers: POWER SONIC: PS-1270, PS-12170, PS‑12180 YUASA: NP7-12, NPG18-12 |
Maintenance | Replace batteries when they fail the Battery Load test |
AUX/FWR Full Wave Rectified | 500 mA at 24 V FWR (17 to 31 VRMS), non‑switched, power-limited, unfiltered, non‑supervised |
AUX/RST Resettable | 500 mA at 24 V FWR (17 to 31 VDC), switched, power-limited, filtered, non‑supervised |
Line impedance for ground fault detection (Option Bus, SLC, NAC, secondary power circuit, City Tie/Local Energy, AUX) | 15 kΩ |
Voltage | Nominal 12 VDC, power-limited, supervised |
Current | 500 mA maximum |
Configuration | 1 Class B |
Circuit wiring distance | 4000 ft. (1219 m) maximum, depending on wire gage and connected devices |
Mainboard NACs | Two (NAC 1 and NAC 2) |
NAC power from panel | Nominal 24 V FWR (17 to 31 VRMS), regulated, power-limited, supervised2.5 A per NAC, maximum current limited to overall 4.0 A shared among AUX power, Option BUS, and NACs |

Battery box/enclosure, 22x21x7.25"
CTN BATB-80
Product No. 4.998.137.931
14 x 20.75 x 7.25" (36 x 53 x 18.5 cm). Battery box/enclosure with shelf holds up to four dry or wet cell batteries. Suitable for residential/commercial fire or burglary applications.

Analog point programmer, hand-held
CTN D5070
Product No. 4.998.800.577
Used to program address settings on EEPROM‑programmable analog devices

Analog sensor base, 4"
CTN FAA-325-B4
Product No. F.01U.133.061
Is combined with analog addressable detectors that use the advanced digital communication protocol to provide early fire warning for life safety and property protection

Analog sensor base with sounder, 6"
CTN FAA-325-B6S
Product No. F.01U.133.063
Contains an addressable sounder which provides an audible alarm in the immediate vicinity and only works in combination with one of the FAH‑325, FAI-325, or FAP‑325 analog sensors

Analog standard base, 4"
CTN FAA-440-B4
Product No. F.01U.163.849
Standard 4-inch base. Used in combination with FAP-440 and FAH-440 detectors to provide early fire warning for life safety and property protection.

Analog heat detector head, fixed/ROR
CTN FAH-440
Product No. F.01U.163.842
Use with FAA‑440 family bases and FAP-1000 Analog Addressable Fire Panels to provide general property protection

Analog photoelectric detector head, 24V
CTN FAP-440
Product No. F.01U.163.843
Analog photoelectric smoke detector used with FAA‑440 bases and FAP-1000 fire panels

Analog detector head, dual, heat/CO
CTN FAP-440-DTC
Product No. F.01U.163.847
Analog dual-photoelectric smoke/heat multi-criteria detector used with FAA‑440 bases and FAP-1000 fire panels

Dual input module for FPA-1000
CTN FLM-325-2I4
Product No. F.01U.133.068
Provides two independent contact monitoring circuits to monitor Normally Open (NO) or Normally Closed (NC) dry contact types of fire alarm devices

Dual relay module, 2A
CTN FLM-325-2R4-2A
Product No. F.01U.168.098
Provides 2 A current at two independently-controlled Form C contacts for a variety of Normally Open and Normally Closed applications, compatible with 254 addresses

Dual relay module with isolator, 2A
CTN FLM-325-2R4-2AI
Product No. F.01U.168.099
Provides 2 A current with built-in short circuit isolator circuitry at two independently-controlled Form C contacts for a variety of Normally Open and Normally Closed applications, compatible with 254 addresses

Dual relay module, 8A
CTN FLM-325-2R4-8A
Product No. F.01U.168.100
Provides 8 A current at two independently-controlled Form C contacts for a variety of Normally Open and Normally Closed applications, compatible with 254 addresses

Dual relay module with isolator, 8A
CTN FLM-325-2R4-8AI
Product No. F.01U.168.101
Provides 8 A current with built-in short circuit isolator circuitry at two independently-controlled Form C contacts for a variety of Normally Open and Normally Closed applications, compatible with 254 addresses

Conventional zone module for FPA-1000
CTN FLM-325-CZM4
Product No. F.01U.133.067
Enables the FACP to interface and monitor up to 25 conventional devices depending on the device type such as two‑wire smoke detectors or pull stations

Contact monitor, class A, 4"
CTN FLM-325-I4-A
Product No. F.01U.168.102
Can be wired for Class A or Class B circuits, mounted to a cover plate for a 4‑inch square or double gang electrical back box, bi‑colored LED provides module status, compatible with 254 addresses

Contact monitor with isolator class A 4"
CTN FLM-325-I4-AI
Product No. F.01U.168.103
Can be wired for Class A or Class B circuits, has built‑in short circuit isolator circuitry, mounted to a cover plate for a 4‑inch square or double gang electrical back box, bi‑colored LED provides module status, compatible with 254 addresses

Contact monitor for mounting in backbox
CTN FLM-325-IM
Product No. F.01U.216.136
Allows compatible fire alarm control panels (FACP) to supervise Form A or B dry contact devices in a polling circuit

Short circuit isolator for FPA-1000
CTN FLM-325-ISO
Product No. F.01U.133.071
Isolates a shorted section on a specific polling circuit from the rest of the system to minimize the loss of communication

Supervised output module, Class A/B
CTN FLM-325-NA4
Product No. F.01U.168.104
Can be wired for Class A or Class B circuits, compatible with 254 addresses

Supervised output module, isolator, A/B
CTN FLM-325-NAI4
Product No. F.01U.168.105
Built-in short circuit isolator circuitry, can be wired for Class A or Class B circuits, compatible with 254 addresses

Analog manual station, single, red
CTN FMM-325A
Product No. F.01U.246.085
The single‑action manual station is UL listed for commercial fire applications and meets Americans with Disabilities Act (ADA) requirements. Set the address on the polling circuit by programming an EEPROM microchip with the D5070 Analog point programmer.

Analog manual station, double, red
CTN FMM-325A-D
Product No. F.01U.246.087
The double‑action manual station is UL listed for commercial fire applications and meets Americans with Disabilities Act (ADA) requirements. Set the address on the polling circuit by programming an EEPROM microchip with the D5070 Analog point programmer.

LCD annunciator FPA-1000 without control
CTN FMR-1000-RA
Product No. F.01U.066.880
LCD annunciator without system control capability for use with the FPA‑1000 Analog Addressable Fire Panels

LCD annunciator FPA-1000 with control
CTN FMR-1000-RCMD
Product No. F.01U.066.879
LCD annunciator with system control capability for use with FPA‑1000 Analog Addressable fire Panels

Plug-in SLC module for FPA-1000
CTN FPE-1000-SLC
Product No. F.01U.073.062
Provides a Signaling Line Circuit (SLC) for connection of analog devices to the FPA‑1000 Analog Addressable Fire Panels

Replacement key for D101 lock set
CTN D102
Product No. F.01U.020.510
The D102 is a replacement key for locks stamped with 1358.

Analog isolator base, 4"
CTN FAA-440-B4-ISO
Product No. F.01U.164.309
4-inch base with built-in isolator. Used in combination with FAP-440 and FAH-440 detectors to provide early fire warning for life safety and property protection.

Analog standard base, 6"
CTN FAA-440-B6
Product No. F.01U.164.308
Standard 6-inch base. Used in combination with FAP-440 and FAH-440 detectors to provide early fire warning for life safety and property protection.

Analog isolator base, 6"
CTN FAA-440-B6-ISO
Product No. F.01U.164.307
6-inch base with built-in isolator. Used in combination with FAP-440 and FAH-440 detectors to provide early fire warning for life safety and property protection.

Analog photoelectric detector head, 24V
CTN FAP-440-T
Product No. F.01U.163.844
Analog photo/heat detector used with FAA‑440 bases and FAP-1000 fire panels

Analog detector head, photo/heat/CO
CTN FAP-440-TC
Product No. F.01U.163.846
Analog photo/heat/CO detector used with FAA‑440 bases and FAP-1000 fire panels

Analog dual-photoelectric detector head
CTN FAP-440-D
Product No. F.01U.163.820
Analog dual-photoelectric smoke detector used with FAA‑440 bases and FAP-1000 fire panels

Analog detector head, dual, photo/heat
CTN FAP-440-DT
Product No. F.01U.163.845
Analog dual-photoelectric smoke/heat multi-sensor detector used with FAA‑440 bases and FAP-1000 fire panels

Network card, 3-Ethernet
CTN FPE-1000-NE
Product No. F.01U.213.933
Ethernet Networking Card for peer‑to‑peer communication in an FPA‑1000‑V2 networked system

Network card, 1-Ethernet 2-fiber optic
CTN FPE-1000-NF
Product No. F.01U.213.943
Fiber Optic Networking Card for peer‑to‑peer communication in an FPA‑1000 networked system

Network card, 1-Ethernet 2-wired
CTN FPE-1000-NW
Product No. F.01U.213.944
Wired Networking Card for peer‑to‑peer communication in an FPA‑1000 networked system

Enclosure with dead-front door
CTN FPM-1000-ENC
Product No. F.01U.214.786
Enclosure with dead front door

Power supply, RNAC 8A 24V
CTN FPP-RNAC-8A-4C
Product No. F.01U.003.444
When connected to a panel’s option bus, the FPP-RNAC-8A-4C adds four additional NFPA 72, Class B or Class A NACs. When connected directly to the NAC output, it is also a NAC power supply for fire-protective signaling systems.

Battery box/enclosure, 22x21x7.25"
CTN BATB-40
Product No. 4.998.137.930
22 x 20.75 x 7.25" (56 x 53 x 18.5 cm). Holds two dry or wet cell batteries. Optional BATB-SHELF battery shelf increases number of batteries. Suitable for residential/commercial fire or burglary applications.

Annunciator, 8 alarm LED
CTN D7030X
Product No. 4.998.800.536
Eight zone LEDs indicate alarm conditions.

Annunciator, 8 LED (2 supervisory)
CTN D7030X-S2
Product No. 4.998.140.386
Two LEDs indicate supervisory conditions, six indicate alarm conditions.

Annunciator, 8 LED (8 supervisory)
CTN D7030X-S8
Product No. 4.998.140.387
All eight zone LEDs (yellow) indicate supervisory conditions.

Annunciator expander, 8 LED
CTN D7032
Product No. 4.998.140.388
Use with D7030X Family LED annunciators

Multiplex octal relay module
CTN D7035
Product No. 4.998.800.539
Provide eight Form C relay outputs (w/o enclosure) for the D7024, FPD-7024, or FPA‑1000 Fire Alarm Control Panels (FACP)

Multiplex octal relay module + enclosure
CTN D7035B
Product No. 4.998.800.540
Provide eight Form C relay outputs (with enclosure) for the D7024, FPD-7024, or FPA‑1000 Fire Alarm Control Panels (FACP)

Octal driver module, 12V
CTN D7048
Product No. 4.998.800.541
Provides eight open-collector transistor outputs (current sinks) to FPA‑1000, FPD-7024, or D7024 FACPs through the control panel's option bus.

Analog sensor base, 6"
CTN FAA-325-B6
Product No. F.01U.133.062
6‑inch (152.4 mm) base for FAH‑325, FAI‑325, and FAP‑325 sensors. US sales only

Kit, analog duct housing w/ smoke head
CTN FAD-325-V2F
Product No. F.01U.335.528
Duct detector housing with an FAD-325-V2F-DH Analog duct smoke head. It’s easy to install with a drill template. The steel sampling tube means there are no screens or filters to clean.

Analog duct smoke head, 2-wire 24V
CTN FAD-325-V2F-DH
Product No. F.01U.335.941
Replacement for the FAD-325-DH Analog duct smoke head for use in FAD-325, FAD-325-R, FAD-325-V2F and FAD-325-V2F-R Analog duct kits

Kit, analog duct housing w/relays & head
CTN FAD-325-V2F-R
Product No. F.01U.335.942
Duct detector housing with an FAD-325-V2F-DH Analog duct smoke head and two sets of Form C alarm relays. It’s easy to install with a drill template. The steel sampling tube means there are no screens or filters to clean.

Plug-in city tie module for FPA-1000
CTN FPE-1000-CITY
Product No. F.01U.076.985
Provides the FPA‑1000 Analog Addressable Fire Panels with two supervised City Tie Local Energy circuits or Reverse Polarity circuits

Semi-flush mounting trim ring
CTN FPM-1000-SFMK
Product No. F.01U.215.088
The FPM-1000-SFMK Semi-flush Mounting Kit includes a trim ring and 4 screw covers.