ISN-SM Seismic Detectors
Seismic detector, 50m²
Commercial Product No.: ISN-SM-50 | Product No.: F.01U.002.248Compatibility: | Better than EN 50130-4 |
HF interference tolerance (EN 61000-4-3): | No alarm or setup at critical frequencies within a range of 1 MHz to 1000 MHz at > 30 V/m. |
Dimensions: | 8.9 cm x 8.9 cm x 2.2 cm |
Weight: | 0.320 kg |
Humidity (EN60721): | Up to 95% relative humidity, not condensing |
Housing protection class (EN 60529, EN 50102): | IP435 |
Temperature (operating): | -40 °C to +70 °C |
Temperature (storage): | -50 °C to +70 °C |
For the test: | Low < 1.5 VDC High > 3.5 VDC |
Test duration (including test transmitter ISN-GMX-S1): | ≤ 3 sec |
Model | Operating radius, Monitoring area |
Concrete | Steel, Concrete |
ISN-SIM-50 | 4 m, 2 m, 50 m2 |
ISN-SIM-80 | 5 m, 2,5 m, 80 m2 |
Alarm relay (changeover contact): | Contact closed in standby mode (opened in the event of an alarm) designed for 30 VDC, 100 mA, resistance < 20 Ohm |
Alarm holding time: | Approx. 2.5 sec |
Tamper switch/wall tamper: | Tamper contact closed in standby mode (opened in the event of tampering) designed for 30 VDC, 100 mA, resistance < 45 Ohm |
Test connection: | Analog integration signal |
Power consumption at 12 VDC: | Alarm: 6 mA |
Power supply monitoring: | 8 VDC to 16 VDC (12 V nominal) |

Floor box for seismic detector
Commercial Type No. ISN-GMX-B0
Product No. F.01U.003.365
Floor box for mounting a seismic detector.
Parts included with this product
Quantity | Component |
---|---|
1 | Seismic detector |
1 | Installation manual |
1 | Installation template |